Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 116.133
Filter
1.
Eur Rev Med Pharmacol Sci ; 28(7): 2654-2661, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38639504

ABSTRACT

OBJECTIVE: This study aimed to explore the effect of flipped venous catheters combined with spinal cord electrical stimulation on functional recovery in patients with sciatic nerve injury. PATIENTS AND METHODS: 160 patients with hip dislocation and sciatic nerve injury were divided into conventional release and flipped catheter + electrical stimulation groups according to the treatment methods (n=80). Motor nerve conduction velocity (MCV) and lower limb motor function were compared. Serum neurotrophic factors brain-derived neurotrophic factor (BDNF) and nerve growth factor (NGF) were compared. The frequency of complications and quality of life were also compared. RESULTS: The MCV levels of the common peroneal nerve and tibial nerve in the flipped catheter + electrical stimulation group were greater than the conventional lysis group (p<0.05). After treatment, the lower extremity motor score (LMEs) in the flipped catheter + electrical stimulation group was greater than the conventional lysis group (p<0.05). The serum levels of BDNF and NGF in the flip catheter + electrical stimulation group were higher than the conventional lysis group (p<0.05). The complication rate in the flipped catheter + electrical stimulation group was lower than in the conventional release group (6.25% vs. 16.25%, p<0.05). The quality-of-life score in the flip catheter + electrical stimulation group was greater than the conventional lysis group (p<0.05). CONCLUSIONS: The flipped venous catheter combined with spinal cord electrical stimulation can improve nerve conduction velocity, lower limb motor function, serum BDNF and NGF levels, reduce complications, and help improve the quality of life of sufferers with sciatic nerve injury. Chictr.org.cn ID: ChiCTR2400080984.


Subject(s)
Brain-Derived Neurotrophic Factor , Sciatic Neuropathy , Rats , Animals , Humans , Brain-Derived Neurotrophic Factor/metabolism , Rats, Sprague-Dawley , Nerve Growth Factor/metabolism , Quality of Life , Sciatic Neuropathy/metabolism , Sciatic Neuropathy/therapy , Spinal Cord/metabolism , Sciatic Nerve , Catheters , Electric Stimulation/methods
2.
J Cardiothorac Surg ; 19(1): 181, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38580985

ABSTRACT

BACKGROUND: A frequent complication of Fontan operations is unilateral diaphragmatic paresis, which leads to hemodynamic deterioration of the Fontan circulation. A potential new therapeutic option is the unilateral diaphragmatic pacemaker. In this study, we investigated the most effective stimulation location for a potential fully implantable system in a porcine model. METHODS: Five pigs (20.8 ± 0.95 kg) underwent implantation of a customized cuff electrode placed around the right phrenic nerve. A bipolar myocardial pacing electrode was sutured adjacent to the motor point and peripherally at the costophrenic angle (peripheral diaphragmatic muscle). The electrodes were stimulated 30 times per minute with a pulse duration of 200 µs and a stimulation time of 300 ms. Current intensity was the only variable changed during the experiment. RESULTS: Effective stimulation occurred at 0.26 ± 0.024 mA at the phrenic nerve and 7 ± 1.22 mA at the motor point, a significant difference in amperage (p = 0.005). Even with a maximum stimulation of 10 mA at the peripheral diaphragm muscle, however, no effective stimulation was observed. CONCLUSION: The phrenic nerve seems to be the best location for direct stimulation by a unilateral thoracic diaphragm pacemaker in terms of the required amperage level in a porcine model.


Subject(s)
Phrenic Nerve , Respiratory Paralysis , Humans , Child , Swine , Animals , Diaphragm , Respiratory Paralysis/etiology , Respiratory Paralysis/therapy , Electrodes , Prostheses and Implants , Electric Stimulation
3.
Sensors (Basel) ; 24(7)2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38610488

ABSTRACT

Near-infrared spectroscopy (NIRS) during repeated limb occlusions is a noninvasive tool for assessing muscle oxidative capacity. However, the method's reliability and validity remain under investigation. This study aimed to determine the reliability of the NIRS-derived mitochondrial power of the musculus vastus lateralis and its correlation with whole-body (cycling) aerobic power (V̇O2 peak). Eleven healthy active men (28 ± 10 y) twice (2 days apart) underwent repeated arterial occlusions to induce changes in muscle oxygen delivery after 15 s of electrical muscle stimulation. The muscle oxygen consumption (mV̇O2) recovery time and rate (k) constants were calculated from the NIRS O2Hb signal. We assessed the reliability (coefficient of variation and intraclass coefficient of correlation [ICC]) and equivalency (t-test) between visits. The results showed high reproducibility for the mV̇O2 recovery time constant (ICC = 0.859) and moderate reproducibility for the k value (ICC = 0.674), with no significant differences between visits (p > 0.05). NIRS-derived k did not correlate with the V̇O2 peak relative to body mass (r = 0.441, p = 0.17) or the absolute V̇O2 peak (r = 0.366, p = 0.26). In conclusion, NIRS provides a reproducible estimate of muscle mitochondrial power, which, however, was not correlated with whole-body aerobic capacity in the current study, suggesting that even if somewhat overlapping, not the same set of factors underpin these distinct indices of aerobic capacity at the different (peripheral and whole-body systemic) levels.


Subject(s)
Quadriceps Muscle , Spectroscopy, Near-Infrared , Male , Humans , Reproducibility of Results , Bicycling , Electric Stimulation
4.
Sensors (Basel) ; 24(7)2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38610589

ABSTRACT

Functional electrical stimulation (FES) devices are widely employed for clinical treatment, rehabilitation, and sports training. However, existing FES devices are inadequate in terms of wearability and cannot recognize a user's intention to move or muscle fatigue. These issues impede the user's ability to incorporate FES devices into their daily life. In response to these issues, this paper introduces a novel wearable FES system based on customized textile electrodes. The system is driven by surface electromyography (sEMG) movement intention. A parallel structured deep learning model based on a wearable FES device is used, which enables the identification of both the type of motion and muscle fatigue status without being affected by electrical stimulation. Five subjects took part in an experiment to test the proposed system, and the results showed that our method achieved a high level of accuracy for lower limb motion recognition and muscle fatigue status detection. The preliminary results presented here prove the effectiveness of the novel wearable FES system in terms of recognizing lower limb motions and muscle fatigue status.


Subject(s)
Muscle Fatigue , Wearable Electronic Devices , Humans , Electromyography , Electric Stimulation , Lower Extremity
5.
Skin Res Technol ; 30(4): e13678, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38616507

ABSTRACT

BACKGROUND: We developed and tested the safety and efficacy of a cosmetic device to improve dark circles using electrical muscle stimulation of the orbicularis oculi muscle. METHODS: Overall, 18 participants (36 eyes) were studied. The following five items were evaluated before and after the intervention:(1) the Clinical Dark Circle Score using clinical findings and photographs, (2) transcutaneous oxygen partial pressure (TcPO2) on the lower eyelid, (3) thermography, (4) two-dimensional laser blood flowmetry, and (5) spectrophotometry. RESULTS: The mean score at baseline was 2.0 ± 0.90 (mean ± standard deviation), and that at the end of the study was 1.2 ± 1.0 (Wilcoxon signed-rank sum test, p < 0.0001), indicating a significant reduction. The spectrophotometer showed a significant decrease in a* and L* values before and after use (Wilcoxon signed-rank sum test, p < 0.0001). There was also a weak negative correlation between the change in score and the change in blood flow and TcPO2 measured using a laser perfusion device (Spearman's rank correlation coefficient, r = -0.32 and -0.39, respectively). Stratified analysis of the baseline score showed a strong negative correlation between the change in score and the change in spectrophotometric a* in the subjects/group with mild periocular dark circles (Spearman's rank correlation coefficient, r = -0.46). Contrastingly, no correlation was observed for any of the measurements in the subjects/group with severe periocular dark circles. After 1 month, no device-related ophthalmic adverse events were observed in any of the participants. CONCLUSION: Electrical muscle stimulation could improve periocular dark circles, especially in the subjects/group with mild periocular dark circles, and was safe.


Subject(s)
Eyelids , Facial Muscles , Humans , Face , Electric Stimulation , Electricity
6.
Eur Respir Rev ; 33(171)2024 Jan 31.
Article in English | MEDLINE | ID: mdl-38508667

ABSTRACT

Although a lung disease, COPD is also associated with extrapulmonary manifestations including, among others, limb muscle dysfunction. Limb muscle dysfunction is a key systemic consequence of COPD that impacts patients' physical activity, exercise tolerance, quality of life and survival. Deconditioning is the main mechanism underlying the development of limb muscle dysfunction in COPD, which can be partially improved with exercise. However, some patients may not be able to tolerate exercise because of incapacitating breathlessness or unwillingness to undertake whole-body exercise. Alternative training modalities that do not give rise to dyspnoea, such as neuromuscular electrical stimulation (NMES), are urged. Over the past 20 years, NMES in COPD has presented conflicting conclusions in meta-analysis. In this review, we try to understand the reason for this result by analysing possible biases and factors that brought conflicting conclusions. We discuss the population (the intervention group, but also the control group), the outcome measures, the frequency of stimulation, the rehabilitation protocol (i.e. NMES alone versus standard care/rehabilitation or NMES plus conventional exercise training versus conventional exercise training alone or NMES versus sham treatment) and the trial design. The main reason for this discrepancy is the lack of dedicated guidelines for NMES. Further research is urged to determine the optimal parameters for an NMES programme. Despite this, NMES appears to be an effective means of enhancing quadriceps strength and exercise capacity in COPD with the potential to break the vicious circle induced by the disease and COPD patients' lifestyle.


Subject(s)
Electric Stimulation Therapy , Pulmonary Disease, Chronic Obstructive , Humans , Pulmonary Disease, Chronic Obstructive/diagnosis , Pulmonary Disease, Chronic Obstructive/therapy , Electric Stimulation Therapy/adverse effects , Electric Stimulation Therapy/methods , Quality of Life , Muscle Strength/physiology , Dyspnea , Electric Stimulation
7.
J Neural Eng ; 21(2)2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38452381

ABSTRACT

Objective.Retinal prostheses evoke visual precepts by electrically stimulating functioning cells in the retina. Despite high variance in perceptual thresholds across subjects, among electrodes within a subject, and over time, retinal prosthesis users must undergo 'system fitting', a process performed to calibrate stimulation parameters according to the subject's perceptual thresholds. Although previous work has identified electrode-retina distance and impedance as key factors affecting thresholds, an accurate predictive model is still lacking.Approach.To address these challenges, we (1) fitted machine learning models to a large longitudinal dataset with the goal of predicting individual electrode thresholds and deactivation as a function of stimulus, electrode, and clinical parameters ('predictors') and (2) leveraged explainable artificial intelligence (XAI) to reveal which of these predictors were most important.Main results.Our models accounted for up to 76% of the perceptual threshold response variance and enabled predictions of whether an electrode was deactivated in a given trial with F1 and area under the ROC curve scores of up to 0.732 and 0.911, respectively. Our models identified novel predictors of perceptual sensitivity, including subject age, time since blindness onset, and electrode-fovea distance.Significance.Our results demonstrate that routinely collected clinical measures and a single session of system fitting might be sufficient to inform an XAI-based threshold prediction strategy, which has the potential to transform clinical practice in predicting visual outcomes.


Subject(s)
Visual Prosthesis , Humans , Artificial Intelligence , Electrodes, Implanted , Retina/physiology , Machine Learning , Electric Stimulation/methods
8.
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue ; 36(3): 298-302, 2024 Mar.
Article in Chinese | MEDLINE | ID: mdl-38538360

ABSTRACT

OBJECTIVE: To evaluate the clinical efficacy of a single-session implantation of spinal cord electrical stimulation with neurophysiological monitoring a spinal cord electrical stimulator under general anesthesia with neurophysiological monitoring for the treatment of high-risk diabetic foot. METHODS: The clinical data of seven patients with high-risk diabetic foot who underwent spinal cord electrical stimulation in neurosurgery ward nine of Tianjin Huanhu Hospital from May 2022 to May 2023 were collected. The operation was performed under general anesthesia with the "C" arm X ray machine guidance and neurophysiological monitoring. The arterial diameter and peak flow rate of lower extremity, lower extremity skin temperature (calf skin temperature, foot skin temperature), visual analog scale (VAS), continuous distance of movement, blood glucose level and toe wound were compared between patients before and after surgery. RESULTS: A total of seven patients with high-risk diabetic foot were included. The diameters and peak flow rates of femoral artery, popliteal artery, anterior tibial artery, posterior tibial artery and dorsal foot artery in both lower limbs were significantly improved after surgery. All patients had different degrees of lower limb pain before operation. After operation, VAS score decreased significantly (1.1±0.9 vs. 6.8±3.4), the pain was significantly relieved, and the calf skin temperature and foot skin temperature were significantly higher than those before surgery [calf skin temperature (centigrade): 33.3±0.9 vs. 30.9±0.7, foot skin temperature (centigrade): 31.4±0.8 vs. 29.1±0.6], fasting blood glucose and postprandial blood glucose were significantly lower than those before surgery [fasting blood glucose (mmol/L): 7.6±1.4 vs. 10.5±1.2, postprandial blood glucose (mmol/L): 9.3±2.3 vs. 13.5±1.1], the differences were statistically significant (all P < 0.01). The lower limb movement of all seven patients was significantly improved after surgery, including one patient who needed wheelchair travel before surgery, and one patient who had intermittent claudication before surgery. Among them, one patient needed wheelchair travel and one patient had intermittent claudication before surgery. All patients could walk normally at 2 weeks after operation. Among the seven patients, two patients had the diabetic foot wound ulceration before surgery, which could not heal for a long time. One month after surgery, blood flow around the foot wound recovered and the healing was accelerated. The wound was dry and crusted around the wound, and the wound healed well. CONCLUSIONS: For diabetic high-risk foot patients who are intolerant to diabetic peripheral neuralgia and local anesthesia spinal cord electrical stimulation test, one-time implantation of spinal cord electrical stimulator under general anesthesia under neurophysiological monitoring can effectively alleviate peripheral neuralgia and other diabetic foot related symptoms, improve lower limb blood supply, and reduce the risk of toe amputation. Clinical practice has proved the effectiveness of this technique, especially for the early treatment of diabetic high-risk foot patients.


Subject(s)
Diabetes Mellitus , Diabetic Foot , Neuralgia , Humans , Diabetic Foot/surgery , Intermittent Claudication , Blood Glucose , Treatment Outcome , Neurophysiological Monitoring , Spinal Cord , Electric Stimulation
9.
Sci Rep ; 14(1): 5458, 2024 03 05.
Article in English | MEDLINE | ID: mdl-38443455

ABSTRACT

Electrical stimulation (ES) has been described as a promising tool for bone tissue engineering, being known to promote vital cellular processes such as cell proliferation, migration, and differentiation. Despite the high variability of applied protocol parameters, direct coupled electric fields have been successfully applied to promote osteogenic and osteoinductive processes in vitro and in vivo. Our work aims to study the viability, proliferation, and osteogenic differentiation of human bone marrow-derived mesenchymal stem/stromal cells when subjected to five different ES protocols. The protocols were specifically selected to understand the biological effects of different parts of the generated waveform for typical direct-coupled stimuli. In vitro culture studies evidenced variations in cell responses with different electric field magnitudes (numerically predicted) and exposure protocols, mainly regarding tissue mineralization (calcium contents) and osteogenic marker gene expression while maintaining high cell viability and regular morphology. Overall, our results highlight the importance of numerical guided experiments to optimize ES parameters towards improved in vitro osteogenesis protocols.


Subject(s)
Mesenchymal Stem Cells , Osteogenesis , Humans , Bone and Bones , Cell Differentiation , Electric Stimulation , Immunologic Factors
10.
Med Eng Phys ; 125: 104127, 2024 03.
Article in English | MEDLINE | ID: mdl-38508804

ABSTRACT

The monitoring of the neuromuscular blockade is critical for patient's safety during and after surgery. The monitoring of neuromuscular blockade often requires the use of Train of Four (TOF) technique. During a TOF test two electrodes are attached to the ulnar nerve, and a series of four electric pulses are applied. The electrical stimulation causes the thumb to twitch, and the amount of twitch varies depending on the amount of neuromuscular blockade in patient's system. Current medical devices used to assist anesthesiologists to perform TOF monitoring often require free hand movement and do not provide accurate or reliable results. The goal of this work is to design, prototype and test a new medical device that provides reliable TOF results when thumb movement is restricted. A medical device that uses a pressurized catheter balloon to detect the response thumb twitch of the TOF test is created. An analytical model, numerical study, and mechanical finger testing were employed to create an optimum design. The design is tested through a pilot human subjects study. No significant correlation is reported with subjects' properties, including hand size.


Subject(s)
Neuromuscular Blockade , Neuromuscular Nondepolarizing Agents , Humans , Neuromuscular Monitoring/methods , Ulnar Nerve/physiology , Electric Stimulation
11.
Int J Mol Sci ; 25(6)2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38542425

ABSTRACT

Brain-stimulation reward, also known as intracranial self-stimulation (ICSS), is a commonly used procedure for studying brain reward function and drug reward. In electrical ICSS (eICSS), an electrode is surgically implanted into the medial forebrain bundle (MFB) in the lateral hypothalamus or the ventral tegmental area (VTA) in the midbrain. Operant lever responding leads to the delivery of electrical pulse stimulation. The alteration in the stimulation frequency-lever response curve is used to evaluate the impact of pharmacological agents on brain reward function. If a test drug induces a leftward or upward shift in the eICSS response curve, it implies a reward-enhancing or abuse-like effect. Conversely, if a drug causes a rightward or downward shift in the functional response curve, it suggests a reward-attenuating or aversive effect. A significant drawback of eICSS is the lack of cellular selectivity in understanding the neural substrates underlying this behavior. Excitingly, recent advancements in optical ICSS (oICSS) have facilitated the development of at least three cell type-specific oICSS models-dopamine-, glutamate-, and GABA-dependent oICSS. In these new models, a comparable stimulation frequency-lever response curve has been established and employed to study the substrate-specific mechanisms underlying brain reward function and a drug's rewarding versus aversive effects. In this review article, we summarize recent progress in this exciting research area. The findings in oICSS have not only increased our understanding of the neural mechanisms underlying drug reward and addiction but have also introduced a novel behavioral model in preclinical medication development for treating substance use disorders.


Subject(s)
Rodentia , Self Stimulation , Animals , Reward , Mesencephalon , Medial Forebrain Bundle , Electric Stimulation
12.
ACS Appl Mater Interfaces ; 16(13): 15773-15782, 2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38526295

ABSTRACT

Chronic wound healing is often a prolonged process with the migration and proliferation of fibroblast cells playing crucial roles. Electrical stimulation (ES) has emerged as a promising physical therapy modality to promote these key events. In this study, we address this issue by employing a triboelectric nanogenerator (TENG) as an electrical stimulator for both drug release and the stimulation of fibroblast cells. The flexible TENG with a sandwich structure was fabricated using a PCL nanofibrous layer, Kapton, and silicon rubber. The TENG could be folded to any degree and twisted, and it could return to its original shape when the force was removed. Cultured cells received ES twice and three times daily for 8 days, with a 30 min interval between sessions. By applying current in a safe range and appropriate time (twice daily), fibroblasts demonstrate an accelerated proliferation and migration rate. These observations were confirmed through cell staining. Additionally, in vitro tests demonstrated the TENG's ability to simultaneously provide ES and release vitamin C from the patch. After 2 h, the amount of released drug increased 2 times in comparison to the control group. These findings provide support for the development of a TENG for the treatment of wounds, which underlines the promise of this new technique for developing portable electric stimulation devices.


Subject(s)
Ascorbic Acid , Fibroblasts , Humans , Drug Liberation , Electric Stimulation , Cell Proliferation
13.
J Neural Eng ; 21(2)2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38530299

ABSTRACT

Objective. The development of electrical pulse stimulations in brain, including deep brain stimulation, is promising for treating various brain diseases. However, the mechanisms of brain stimulations are not yet fully understood. Previous studies have shown that the commonly used high-frequency stimulation (HFS) can increase the firing of neurons and modulate the pattern of neuronal firing. Because the generation of neuronal firing in brain is a nonlinear process, investigating the characteristics of nonlinear dynamics induced by HFS could be helpful to reveal more mechanisms of brain stimulations. The aim of present study is to investigate the fractal properties in the neuronal firing generated by HFS.Approach. HFS pulse sequences with a constant frequency 100 Hz were applied in the afferent fiber tracts of rat hippocampal CA1 region. Unit spikes of both the pyramidal cells and the interneurons in the downstream area of stimulations were recorded. Two fractal indexes-the Fano factor and Hurst exponent were calculated to evaluate the changes of long-range temporal correlations (LRTCs), a typical characteristic of fractal process, in spike sequences of neuronal firing.Mainresults. Neuronal firing at both baseline and during HFS exhibited LRTCs over multiple time scales. In addition, the LRTCs significantly increased during HFS, which was confirmed by simulation data of both randomly shuffled sequences and surrogate sequences.Conclusion. The purely periodic stimulation of HFS pulses, a non-fractal process without LRTCs, can increase rather than decrease the LRTCs in neuronal firing.Significance. The finding provides new nonlinear mechanisms of brain stimulation and suggests that LRTCs could be a new biomarker to evaluate the nonlinear effects of HFS.


Subject(s)
Hippocampus , Neurons , Rats , Animals , Rats, Sprague-Dawley , Neurons/physiology , Hippocampus/physiology , Axons/physiology , CA1 Region, Hippocampal/physiology , Electric Stimulation/methods
14.
J Neural Eng ; 21(2)2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38457841

ABSTRACT

Objective.Retinal implants use electrical stimulation to elicit perceived flashes of light ('phosphenes'). Single-electrode phosphene shape has been shown to vary systematically with stimulus parameters and the retinal location of the stimulating electrode, due to incidental activation of passing nerve fiber bundles. However, this knowledge has yet to be extended to paired-electrode stimulation.Approach.We retrospectively analyzed 3548 phosphene drawings made by three blind participants implanted with an Argus II Retinal Prosthesis. Phosphene shape (characterized by area, perimeter, major and minor axis length) and number of perceived phosphenes were averaged across trials and correlated with the corresponding single-electrode parameters. In addition, the number of phosphenes was correlated with stimulus amplitude and neuroanatomical parameters: electrode-retina and electrode-fovea distance as well as the electrode-electrode distance to ('between-axon') and along axon bundles ('along-axon'). Statistical analyses were conducted using linear regression and partial correlation analysis.Main results.Simple regression revealed that each paired-electrode shape descriptor could be predicted by the sum of the two corresponding single-electrode shape descriptors (p < .001). Multiple regression revealed that paired-electrode phosphene shape was primarily predicted by stimulus amplitude and electrode-fovea distance (p < .05). Interestingly, the number of elicited phosphenes tended to increase with between-axon distance (p < .05), but not with along-axon distance, in two out of three participants.Significance.The shape of phosphenes elicited by paired-electrode stimulation was well predicted by the shape of their corresponding single-electrode phosphenes, suggesting that two-point perception can be expressed as the linear summation of single-point perception. The impact of the between-axon distance on the perceived number of phosphenes provides further evidence in support of the axon map model for epiretinal stimulation. These findings contribute to the growing literature on phosphene perception and have important implications for the design of future retinal prostheses.


Subject(s)
Retina , Visual Prosthesis , Humans , Retrospective Studies , Retina/physiology , Phosphenes , Axons , Electric Stimulation , Perception
15.
J Neural Eng ; 21(2)2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38537268

ABSTRACT

Objective. Intracortical microstimulation (ICMS) can be an effective method for restoring sensory perception in contemporary brain-machine interfaces. However, the mechanisms underlying better control of neuronal responses remain poorly understood, as well as the relationship between neuronal activity and other concomitant phenomena occurring around the stimulation site.Approach. Different microstimulation frequencies were investigatedin vivoon Thy1-GCaMP6s mice using widefield and two-photon imaging to evaluate the evoked excitatory neural responses across multiple spatial scales as well as the induced hemodynamic responses. Specifically, we quantified stimulation-induced neuronal activation and depression in the mouse visual cortex and measured hemodynamic oxyhemoglobin and deoxyhemoglobin signals using mesoscopic-scale widefield imaging.Main results. Our calcium imaging findings revealed a preference for lower-frequency stimulation in driving stronger neuronal activation. A depressive response following the neural activation preferred a slightly higher frequency stimulation compared to the activation. Hemodynamic signals exhibited a comparable spatial spread to neural calcium signals. Oxyhemoglobin concentration around the stimulation site remained elevated during the post-activation (depression) period. Somatic and neuropil calcium responses measured by two-photon microscopy showed similar dependence on stimulation parameters, although the magnitudes measured in soma was greater than in neuropil. Furthermore, higher-frequency stimulation induced a more pronounced activation in soma compared to neuropil, while depression was predominantly induced in soma irrespective of stimulation frequencies.Significance. These results suggest that the mechanism underlying depression differs from activation, requiring ample oxygen supply, and affecting neurons. Our findings provide a novel understanding of evoked excitatory neuronal activity induced by ICMS and offer insights into neuro-devices that utilize both activation and depression phenomena to achieve desired neural responses.


Subject(s)
Calcium , Visual Cortex , Mice , Animals , Photic Stimulation , Oxyhemoglobins , Neurons/physiology , Electric Stimulation/methods
16.
J Neural Eng ; 21(2)2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38547529

ABSTRACT

Objective.Neuromodulation, particularly electrical stimulation, necessitates high spatial resolution to achieve artificial vision with high acuity. In epiretinal implants, this is hindered by the undesired activation of distal axons. Here, we investigate focal and axonal activation of retinal ganglion cells (RGCs) in epiretinal configuration for different sinusoidal stimulation frequencies.Approach.RGC responses to epiretinal sinusoidal stimulation at frequencies between 40 and 100 Hz were tested inex-vivophotoreceptor degenerated (rd10) isolated retinae. Experiments were conducted using a high-density CMOS-based microelectrode array, which allows to localize RGC cell bodies and axons at high spatial resolution.Main results.We report current and charge density thresholds for focal and distal axon activation at stimulation frequencies of 40, 60, 80, and 100 Hz for an electrode size with an effective area of 0.01 mm2. Activation of distal axons is avoided up to a stimulation amplitude of 0.23µA (corresponding to 17.3µC cm-2) at 40 Hz and up to a stimulation amplitude of 0.28µA (14.8µC cm-2) at 60 Hz. The threshold ratio between focal and axonal activation increases from 1.1 for 100 Hz up to 1.6 for 60 Hz, while at 40 Hz stimulation frequency, almost no axonal responses were detected in the tested intensity range. With the use of synaptic blockers, we demonstrate the underlying direct activation mechanism of the ganglion cells. Finally, using high-resolution electrical imaging and label-free electrophysiological axon tracking, we demonstrate the extent of activation in axon bundles.Significance.Our results can be exploited to define a spatially selective stimulation strategy avoiding axonal activation in future retinal implants, thereby solving one of the major limitations of artificial vision. The results may be extended to other fields of neuroprosthetics to achieve selective focal electrical stimulation.


Subject(s)
Retina , Visual Prosthesis , Retina/physiology , Retinal Ganglion Cells/physiology , Microelectrodes , Axons/physiology , Electric Stimulation/methods
17.
J Neurosci Methods ; 405: 110106, 2024 May.
Article in English | MEDLINE | ID: mdl-38453060

ABSTRACT

BACKGROUND: Single-pulse electrical stimulation (SPES) is an established technique used to map functional effective connectivity networks in treatment-refractory epilepsy patients undergoing intracranial-electroencephalography monitoring. While the connectivity path between stimulation and recording sites has been explored through the integration of structural connectivity, there are substantial gaps, such that new modeling approaches may advance our understanding of connectivity derived from SPES studies. NEW METHOD: Using intracranial electrophysiology data recorded from a single patient undergoing stereo-electroencephalography (sEEG) evaluation, we employ an automated detection method to identify early response components, C1, from pulse-evoked potentials (PEPs) induced by SPES. C1 components were utilized for a novel topology optimization method, modeling 3D electrical conductivity to infer neural pathways from stimulation sites. Additionally, PEP features were compared with tractography metrics, and model results were analyzed with respect to anatomical features. RESULTS: The proposed optimization model resolved conductivity paths with low error. Specific electrode contacts displaying high error correlated with anatomical complexities. The C1 component strongly correlated with additional PEP features and displayed stable, weak correlations with tractography measures. COMPARISON WITH EXISTING METHOD: Existing methods for estimating neural signal pathways are imaging-based and thus rely on anatomical inferences. CONCLUSIONS: These results demonstrate that informing topology optimization methods with human intracranial SPES data is a feasible method for generating 3D conductivity maps linking electrical pathways with functional neural ensembles. PEP-estimated effective connectivity is correlated with but distinguished from structural connectivity. Modeled conductivity resolves connectivity pathways in the absence of anatomical priors.


Subject(s)
Electroencephalography , Evoked Potentials , Humans , Evoked Potentials/physiology , Electroencephalography/methods , Electrocorticography/methods , Brain Mapping/methods , Electric Stimulation/methods , Brain/diagnostic imaging
18.
Am J Physiol Regul Integr Comp Physiol ; 326(5): R438-R447, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38525536

ABSTRACT

The force drop after transcranial magnetic stimulation (TMS) delivered to the motor cortex during voluntary muscle contractions could inform about muscle relaxation properties. Because of the physiological relation between skeletal muscle fiber-type distribution and size and muscle relaxation, TMS could be a noninvasive index of muscle relaxation in humans. By combining a noninvasive technique to record muscle relaxation in vivo (TMS) with the gold standard technique for muscle tissue sampling (muscle biopsy), we investigated the relation between TMS-induced muscle relaxation in unfatigued and fatigued states, and muscle fiber-type distribution and size. Sixteen participants (7F/9M) volunteered to participate. Maximal knee-extensor voluntary isometric contractions were performed with TMS before and after a 2-min sustained maximal voluntary isometric contraction. Vastus lateralis muscle tissue was obtained separately from the participants' dominant limb. Fiber type I distribution and relative cross-sectional area of fiber type I correlated with TMS-induced muscle relaxation at baseline (r = 0.67, adjusted P = 0.01; r = 0.74, adjusted P = 0.004, respectively) and normalized TMS-induced muscle relaxation as a percentage of baseline (r = 0.50, adjusted P = 0.049; r = 0.56, adjusted P = 0.031, respectively). The variance in the normalized peak relaxation rate at baseline (59.8%, P < 0.001) and in the fatigue resistance (23.0%, P = 0.035) were explained by the relative cross-sectional area of fiber type I to total fiber area. Fiber type I proportional area influences TMS-induced muscle relaxation, suggesting TMS as an alternative method to noninvasively inform about skeletal muscle relaxation properties.NEW & NOTEWORTHY Transcranial magnetic stimulation (TMS)-induced muscle relaxation reflects intrinsic muscle contractile properties by interrupting the drive from the central nervous system during voluntary muscle contractions. We showed that fiber type I proportional area influences the TMS-induced muscle relaxation, suggesting that TMS could be used for the noninvasive estimation of muscle relaxation in unfatigued and fatigued human muscles when the feasibility of more direct method to study relaxation properties (i.e., muscle biopsy) is restricted.


Subject(s)
Muscle, Skeletal , Transcranial Magnetic Stimulation , Humans , Transcranial Magnetic Stimulation/methods , Electric Stimulation/methods , Muscle, Skeletal/physiology , Muscle Relaxation , Muscle Fatigue/physiology , Muscle Contraction/physiology , Isometric Contraction/physiology , Muscle Fibers, Skeletal , Electromyography/methods
19.
Neurosci Lett ; 827: 137735, 2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38513935

ABSTRACT

Patients with post-stroke hemiplegia often exhibit reduced ability to maintain sitting balance, a crucial factor for predicting prognosis. Galvanic vestibular stimulation (GVS) influences postural control by stimulating vestibular organ. Although several studies have focused on GVS in static postures, no studies have demonstrated the influence of GVS on righting reactions. Therefore, we aimed to investigate the effects of GVS on postural righting reactions in seated patients with stroke-induced hemiplegia. Using a vertical board (VB), righting reactions were induced by tilting the VB at 10° after patients sat for 1 min. Patients adjusted their bodies until feeling vertical upon prompt. Twenty-two left hemiplegic patients with cerebrovascular disease participated, divided into two groups undergoing right cathode GVS (RC-GVS) followed by left cathode GVS or vice versa, preceded by sham stimulation. Centre of pressure and the joint angle were measured. During the postural righting reactions towards the paralysed side, RC-GVS enhanced the righting reactions and moved the mean position on the x-axis (COPx) to the right and the mean position on the y-axis (COPy) to the front. During the postural righting reaction towards the right side, RC-GVS induced resistance against the righting reaction, COPx was deflected to the right, COPy was deflected backward, and the angle of the neck tilt increased. The findings revealed that GVS with anodal stimulation on the paralysed side could promote righting reactions in patients with post-stroke hemiplegia. SIGNIFICANCE STATEMENT: The study findings suggest that using the contralesional placement of the anode promotes righting reactions, and galvanic vestibular stimulation can induce joint movements in the neck and trunk by polarising it to act as resistance against righting reactions.


Subject(s)
Stroke , Vestibule, Labyrinth , Humans , Hemiplegia/etiology , Vestibule, Labyrinth/physiology , Movement , Postural Balance/physiology , Stroke/complications , Electric Stimulation
20.
J Neural Eng ; 21(2)2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38537271

ABSTRACT

Objective.Neuromuscular electrical stimulation (NMES) is widely used for motor function rehabilitation in stroke survivors. Compared with the conventional motor point (MP) stimulation, the stimulation at the proximal segment of the peripheral nerve (PN) bundles has been demonstrated to have multiple advantages. However, it is not known yet whether the PN stimulation can increase the cortical activation level, which is crucial for motor function rehabilitation.Approach.The current stimuli were delivered transcutaneously at the muscle belly of the finger flexors and the proximal segment of the median and ulnar nerves, respectively for the MP and PN stimulation. The stimulation intensity was determined to elicit the same contraction levels between the two stimulation methods in 18 healthy individuals and a stroke patient. The functional near-infrared spectroscopy and the electromyogram were recorded to compare the activation pattern of the sensorimotor regions and the target muscles.Main Results.For the healthy subjects, the PN stimulation induced significantly increased concentration of the oxygenated hemoglobin in the contralateral sensorimotor areas, and enhanced the functional connectivity between brain regions compared with the MP stimulation. Meanwhile, the compound action potentials had a smaller amplitude and the H-reflex became stronger under the PN stimulation, indicating that more sensory axons were activated in the PN stimulation. For the stroke patient, the PN stimulation can elicit finger forces and induce activation of both the contralateral and ipsilateral motor cortex.Conclusions. Compared with the MP stimulation, the PN stimulation can induce more cortical activation in the contralateral sensorimotor areas possibly via involving more activities in the central pathway.Significance.This study demonstrated the potential of the PN stimulation to facilitate functional recovery via increasing the cortical activation level, which may help to improve the outcome of the NMES-based rehabilitation for motor function recovery after stroke.


Subject(s)
Sensorimotor Cortex , Stroke , Humans , Muscle, Skeletal/physiology , Electric Stimulation/methods , Electromyography
SELECTION OF CITATIONS
SEARCH DETAIL
...